APC Smart-UPS On-Line, 10kVA/10kW, 230V, 2x C13+1x C19+HW, NMC, Preventive Maint, EcoStruxure IT Expert, W/O rail kit SRTG10KXLI-PMITE

NGN 6,090,000.00

Same Day Delivery

In stock
SKU
APC Smart-UPS On-Line
  • Output

    Max Configurable Power (Watts)
    10.0kWatts / 10.0kVA
    Output Voltage Note
    Configurable for 220 : 230 or 240 nominal output voltage
    Output Voltage Distortion
    Less than 2 %
    Output Frequency (sync to mains)
    50/60 Hz +/- 3 Hz Sync to mains
    Other Output Voltages
    220 V
    Load Crest Factor
    3 : 1
    Topology
    Double conversion online
    Waveform type
    Sine wave
    Bypass
    Internal bypass (automatic and manual)

    Input

    Input frequency
    40 - 70 Hz Auto-sensing
    Input voltage range for main operations
    160 - 285V
    Other Input Voltages
    220 V
    Maximum Short Circuit Withstand (Icw)
    40.0kAmps

    Batteries & Runtime

    Battery type
    Lead-acid battery
    Typical recharge time
    4hour(s)
    Nominal Battery Voltage
    +/- 96 V
    Expected Battery Life (years)
    3 - 5
    Battery Charge Power (Watts)
    431 Watts
    Extendable Run Time
    1

     

     
     
     

For Bulk Orders Call (01) 4536190.

Sales End In:
  • days
  • Hours
  • Minutes
APC

Availability

Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Scalable runtime
Allows additional run time to be quickly added as needed.

Manageability

Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
LED status indicators
Quickly understand unit and power status with visual indicators.
Serial connectivity
Provides management of the UPS via a serial port.
Intelligent Card Slot
Customize UPS capabilities with management cards.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.

Marketing features

Low operating and maintenance costs with proven reliability and intelligent battery management .
Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
Avoids costly power problems by keeping your IT equipment and data protected and available .
Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
Save time with easy and convenient remote/network accessibility.
Network manageable via serial, USB or Ethernet. Includes Powerchute® Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
Peace of mind that comes with full equipment compatibility and reliability of a leader
Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.

Protection

Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Cold-start capable
Provides temporary battery power when the utility power is out.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Serviceability

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

More Information

More Information
ManufacturerCollins & Hayes

Reviews

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account